Features

  • Large clear LCD (height 25.4mm × 10mm)
  • LED Back light, longer life and energy saving
  • Auto zero tracking
  • Weighing calibration in both kilogram and pound modes
  • High resolution switch function to display 10 times the divisions
  • Weighing unit change function
  • Data accumulation function
  • Multi-interval or multi-range mode
  • Animal weighing mode
  • Pre-tare entry function
  • Adjustable digital filtering
  • Can connect with up to four 350-ohm load cells
  • Capable of connecting with 6-wire load cells
  • Convenient to operate power switch in the front panel
ConfigurationOrderSize (WidthxDepthxHeight)Weight(kg)
Mains AC AdaptorEP100DI0000XXX193 x 50 x 1340.7
Mains Adaptor/Rechargeable Battery/RS232EP100DI232RBAT193 x 50 x 1340.7

Analog Specification

  • Load Cell Excitation: DC 5V 5% 60mA (Up to Four 350Ω Load Cells)
  • Max. Load Cell Input Voltage: 16 mV
  • Input Sensitivity: 0.12V/D or more
  • Conversion Rate: Approximately 100 times/sec.(max.)
  • Resolution: 19 bits

Digital Specification

  • Display: LCD, 6 digits, height 25.4x10mm, LEDback light
  • Display Update: 50 times/sec. (max.)
  • Display Range: – 999999 ~ 999999
  • Min. Division: 1, 2, 5, 10, 20, 50
  • Decimal Point: 0, 0.0, 0.00, 0.000, 0.0000
  • Memory: Calibration parameter and function
  • Setting are all stored in EEPROM.

Optional Interface

  • OP-01 RS-232 / RS-485 (Includes RTC Function)

Power Requirement

  • Mains Adaptor.: Input 120/230VAC 50~60Hz, output 9V/1000mA
  • 6V/5pcs Hi-MH rechargeable battery kit (1800mA/1hr)
  • Max. Power Consumption (with rechargeable battery):
    • 120mA (with 4 Load Cells + backlight + RS-232 interface) →15 hours
    • 50mA (with 1 Load Cell + no backlight + no RS-232 interface) →36 hours

Other

  • Operating Temperature: -10C ~ 40C
  • Operating Humidity: < 85% R.H.
  • Dimensions: W 49.5 x L193 x H134 (mm)
  • Weight: 700 (g)